Comfortable House
Building components
New Materials
  Fibrolite Technical Characteristics

Technical Characteristics of cement Fibroliteа are in the table below

Characterictic  GB1  GB2  GB3
Thickness, mm 15 - 100 15 - 50 10 - 35
Density, kg/m3  360 - 570 600 - 800 850 - 1100

Thickness swelling:

from 30% to 65% of relative

air humidity, less than

from 65% to 85% of relative

air humidity, less than

 - -

 

 

0,5%

 

0,4%

Thickness swelling during 24h

%, less than

6
5
4
Water absorbtion during 24h, %, less than
45
40
20
Elasticity module, MPa, not less than
300
1000 3500
Bending strength, MPa, not less than
0,4 - 0,8
3
12
Compression strength, MPa, not less than
0,15 - 0,20
4
15

Tensile strength 

MPa, not less than

0,1
0,2
0,35
Thermal conductivity, watt/(m oK)
0,063
0,13
0,17
Specific heat, kilojoule/(kg oK)
2
2,4
2,9

Vapor permeabilty calculated coefficient,

mg/(m Pa)

 0,130,06
0,03
Rigidity, MPa, not less than
12
26
40
Impact toughness, kilojoile/m2, not less than
 35
1,7

specific pull-out resistance 

of screws, N/mm, not less than

8 - 10
20 - 22
77

Frost resistance (durability loss during

bending after 50 cycles), %, not less than

-
-
10

Linear growth/shrinkage:

from dry condition to wet during 66h

from fully moisture soaked condition to 20°С and

68% of relative air humidity

from 20°С 68% of relative air humidity 

to dry condition in exsiccator

 

-

 

-

 

-

 

-

 

-

 

-

 

0,354%

 

-0,123%

 

-0,203%

Homepage  -   Contacts  -   Sitemap  -   Our Partners
«Bausapiens» system
for Developers  -   for Privat builders  -   for Contractors  -   for Engineering organizations
Русская версия  -   English version

This site is optimized for modern browsers, such as Chrome, Firefox or Opera,
if you are using Internet Explorer, some content can be damaged.
Solved in 2001. (c) SioTech Global GmbH. design by Solve